Lithium-ion batteries require sophisticated management systems to control proper charging and discharging. Stafl Systems' BMS products cover high voltage packs up to 1000 V and low voltage packs from 10 V to 60 V. Every product is configurable to your cells, and can be customized to fit your pack and application.
UNRIVALED ACCURACY
 
The Stafl Systems modular BMS1000 Series Battery Management System consists of one BMS Master Module and an application-specific number of BMS Monitor Modules.
1X Master BMS Unit
Communicates with outside system via CAN 2.0B
Manages pre-charging and contactors
Monitors pack voltages
1-64X Monitor BMS Units
Measures cell voltages and temperatures
Balances cells
Communicates with Master BMS via internal data link
BMS PRODUCT CATALOG
 
Stafl Systems Battery Management Systems require one BMS Master Module (e.g. BMS1000M) and 1 to 64 BMS Monitor Modules (e.g. BMS1101S / BMS1102S) to function.
 
Ready to collaborate?
Get in Touch
 
precise engineering
Features
Scalable from 12 to 256 Series Cells
Temperature Sensor for Each Cell Group
Supports up to 1000V Systems
Low Steady State Cell Voltage Measurement Error (<2.0 mV)
Individual Cell Group Balancing Resistors
Externally Powered for Low Quiescent Battery Current
High Current Shunt Monitor Circuit for Accurate Pack Current Sensing
Pack Level Voltage Monitoring
Integrated Isolation Fault Monitor Circuit
SEE ALSO: BMS Product Family Brochure (PDF)
Typical System Diagram
COUNTLESS APPLICATIONS
 
hIGH VOLTAGE
While a vehicle’s power system sees a battery pack as a single, high-voltage battery — charging and discharging the entire battery pack at once — the battery control system must consider each battery’s condition independently.
LOW VOLTAGE
A proper system will continuously monitor important battery parameters for low voltage applications, while dealing with the varying power demands of the many aspects of operation and optimizing the usage of the battery.
stationary storage
The service life of a battery pack is tied to the weakest battery in the system. In the balancing process, each of the batteries within the string is maintained at optimal voltage levels, eliminating the ill-effects of improper charging.
Full-featured string controller for packs up to 1000 V and 600 series cells
6 safety rated contactor drives and pyroswitch output with safety rated redundant switching
Redundant pack voltage, current and isolation measurement
68 I/O, plus 3x CAN-FD, RS-485 and optional Ethernet
Designed to ISO 13849 PL d
Product Page 🡆