Summary
The BMS2101 Cell Monitor mounts on your battery modules and works with a BMS2000 String Controller to measure and balance every cell. Each board covers up to 16 cells in series, with redundant measurements and ±2.25 mV accuracy.
Its high-current balancing, up to 1 A per cell, brings large-format cells into balance quickly, making it the right fit for big packs and demanding duty cycles.
DOWNLOADS: BMS Product Family Brochure (PDF)
FEATURES
Standard BMS21xx Cell Harness Pinout
2x isoSPI Ports for Ring or Daisy Chain
1000 V Transformer Isolation
Powered from Module, 11 V - 80 V
On-Board EEPROM & Balancing Resistor Temperature Sensors
Conformally Coated
16 Cell Battery Monitor with Passive Balancing
Redundant Cell Voltage ADCs
±2.25 mV Lifetime Cell Voltage Measurement Error
High-Current Passive Balancing, up to 1 A per Cell, with PWM Control
Bottom-Side Balancing Resistors for Heatsinking to the Pack
4 NTC Thermistor Inputs, Configurable as 2 Redundant Pairs
Cell Inputs Configurable for Busbar Voltage Drop Sensing
Specifications
| Parameter | Conditions | Min | Typical | Max | Units |
|---|---|---|---|---|---|
| Module Supply Voltage | 11 | 80 | V | ||
| Cell Input Voltage | Differential | -2 | 5.5 | V | |
| Cell Voltage Measurement Error | Lifetime, VCELL ≤ 3.3 V | ±2.25 | mV | ||
| Cell Voltage Resolution | 0.15 | mV | |||
| Balancing Current | Heat-sunk | 1 | A | ||
| NTC Temperature Range | -40 | 125 | °C | ||
| Cell Voltage Sampling Rate | All cells, 8-sample average, redundant ADC; while operating |
20 | Hz | ||
| Temperature Sampling Rate | All NTC inputs; while operating | 10 | Hz | ||
| Isolation | Working voltage, IEC 60664-1 | 1000 | VDC | ||
| Operating Temperature | -40 | 105 | °C | ||
| Dimensions | 160 x 60 | 160 x 60 | mm |