BMS2101

$400.00
Cell Monitor — High Voltage
  • Monitors and balances up to 16 series cells

  • High-current passive balancing, up to 1 A per cell

  • Redundant cell voltage measurement, ±2.25 mV lifetime accuracy

  • 4 temperature inputs, or 2 redundant pairs

  • Wide 11 V to 80 V module supply

  • Bottom-side heatsinking to the pack for full balancing current

Product Page 🡆

Cell Monitor — High Voltage
  • Monitors and balances up to 16 series cells

  • High-current passive balancing, up to 1 A per cell

  • Redundant cell voltage measurement, ±2.25 mV lifetime accuracy

  • 4 temperature inputs, or 2 redundant pairs

  • Wide 11 V to 80 V module supply

  • Bottom-side heatsinking to the pack for full balancing current

Product Page 🡆


Summary

The BMS2101 Cell Monitor mounts on your battery modules and works with a BMS2000 String Controller to measure and balance every cell. Each board covers up to 16 cells in series, with redundant measurements and ±2.25 mV accuracy.

Its high-current balancing, up to 1 A per cell, brings large-format cells into balance quickly, making it the right fit for big packs and demanding duty cycles.

DOWNLOADS:   BMS Product Family Brochure (PDF)


FEATURES

  • Standard BMS21xx Cell Harness Pinout

  • 2x isoSPI Ports for Ring or Daisy Chain

  • 1000 V Transformer Isolation

  • Powered from Module, 11 V - 80 V

  • On-Board EEPROM & Balancing Resistor Temperature Sensors

  • Conformally Coated

  • 16 Cell Battery Monitor with Passive Balancing

  • Redundant Cell Voltage ADCs

  • ±2.25 mV Lifetime Cell Voltage Measurement Error

  • High-Current Passive Balancing, up to 1 A per Cell, with PWM Control

  • Bottom-Side Balancing Resistors for Heatsinking to the Pack

  • 4 NTC Thermistor Inputs, Configurable as 2 Redundant Pairs

  • Cell Inputs Configurable for Busbar Voltage Drop Sensing


Specifications

Parameter Conditions Min Typical Max Units
Module Supply Voltage 11 80 V
Cell Input Voltage Differential -2 5.5 V
Cell Voltage Measurement Error Lifetime, VCELL ≤ 3.3 V ±2.25 mV
Cell Voltage Resolution 0.15 mV
Balancing Current Heat-sunk 1 A
NTC Temperature Range -40 125 °C
Cell Voltage Sampling Rate All cells, 8-sample average,
redundant ADC; while operating
20 Hz
Temperature Sampling Rate All NTC inputs; while operating 10 Hz
Isolation Working voltage, IEC 60664-1 1000 VDC
Operating Temperature -40 105 °C
Dimensions 160 x 60 160 x 60 mm